Manufacturer: Micropolis |
Model: 3391AV |
TD# 470118 |
Interface... ULTRA SCSI-3 |
Formatted Capacity... 9,103 MB |
Cylinders |
4811 |
Heads |
22 |
Sectors |
Variable |
Landing Zone |
Max Cyl |
AV Data Rate Max.
Sustained |
9.5 |
AV Data Rate Min.
Sustained |
6.5 |
Encoding Method |
RLL1,7 |
Xfer/Mb(async/sync) |
10/20 |
MTBF (Hr X 1000) |
650 |
Form factor |
3.5" |
Novell Y/N |
N |
Height |
1" |
Power (Typical) |
14W |
Power (Max) |
17W |
Speed |
7200 |
Avg seek (ms) |
7.9 |
Cache |
2000k |
Mfg. Warranty |
5 YRS |
Copyright ⌐ 1996, 1997 Tech
Data Corporation
Configuration and Jumper
Options
(Pin numbers refer to the
Option Jumper Block)
- SCSI ID Selection
- Jumpers at ID0, ID1, and ID2 (pins 3/4,
5/6, and 7/8) select the SCSI address. Each SCSI device
on one Host Adapter must have a unique address.
SCSI Bus Addresses* |
ID0 |
ID1 |
ID2 |
SCSI ID |
OUT |
OUT |
OUT |
O |
IN |
OUT |
OUT |
1 |
OUT |
IN |
OUT |
2 |
IN |
IN |
OUT |
3 |
OUT |
OUT |
IN |
4 |
IN |
OUT |
IN |
5 |
OUT |
IN |
IN |
6 |
IN |
IN |
IN |
7 |
- Interface Termination
- Jumper installed at W4 (27/28) (Default) -
The drive provides termination for the interface lines;
onboard termination is electrically enabled.
- Jumper omitted at W4 (27/28) - The drive
does not provide termination for the interface lines;
onboard termination is electrically disabled.
- Terminator Power
- Jumper installed at W1 (Default) - The
drive provides terminator power.
- Jumper installed at W2 - The host provides
terminator power (via Interface Connector J1A).
- Jumper installed at W3 - The drive
provides terminator power (via J1A) to the SCSI Bus.
- Spindle Control (SP0)
- Jumper installed at SP0, jumper omitted at
SP1 - The spindle motor starts when SCSI ‘START
UNIT’ command is received.
- Jumpers omitted at SP0 (Default) and at
SP1 - The spindle motor starts at power-on.
- Spindle Delay (SP1)
- Jumper installed at SP1, jumper omitted at
SP0 Spindle motor start-up is delayed, based on SCSI ID
(12 seconds per SCSI ID).
- Jumpers omitted at SP1 (Default) and at
SP0 - The spindle motor starts at power-on.
- Write Protect
- A jumper at WP (Pins 15 and 16) selects
the write protect option.
Jumper |
The drive is
write protected. |
No Jumper |
The drive is
not write protected. (Default) |
- Parity
- A jumper at PTY (Pins 17 and 18) selects
the bus parity check option.
Jumper
installed at PTY |
- The drive
neither generates nor detects parity. |
Jumper omitted
at PTY (Default) |
- The drive
generates parity and has parity detection
enabled. |
- Remote LED
- Open-collector output - Used to drive a
user-supplied LED to indicate the drive is active.
[Main